    Ground Loop - can't I just go direct to terminal?

    I'm trying to eliminate my ground loop, alternator whine problem and I'm thinking I'll buy a bunch of wire, and just connect the ground of my P1900 directly back to the battery, i shouldn't hear anything, right? Just the sweet sound of music, correct? I mean, there's no better ground than "ground" itself. (Aside from having RF interfence, but that's a different story)

  2. #2
    Maximum Bitrate crooper's Avatar
    Join Date
    Nov 2006
    Location
    Everett, WA
    Posts
    467
    You need to do some more reading. The "quality" of the ground connection isn't the problem, it's having signal wires in close proximity to power wires and getting crosstalk. Unless you're using like 0 awg wire I don't think there's any real advantage to having wire returning to the battery instead of good bare metal chassis grounds. If you're worried about having good grounds, you could do the Big 3 upgrade in your engine bay.

  3. #3
    Low Bitrate
    Join Date
    Apr 2004
    Location
    Dublin
    Posts
    111
    I had a problem with the buzzing sound and i purchased a 'ground loop isolator' for 15 euro that completely solved the issue i was having. Im in Europe so i dont know of places that sell them there , but google it.

  4. #4
    Newbie
    Join Date
    Mar 2004
    Location
    Australia
    Posts
    49
    Quote Originally Posted by crooper View Post
    You need to do some more reading. The "quality" of the ground connection isn't the problem, it's having signal wires in close proximity to power wires and getting crosstalk. Unless you're using like 0 awg wire I don't think there's any real advantage to having wire returning to the battery instead of good bare metal chassis grounds. If you're worried about having good grounds, you could do the Big 3 upgrade in your engine bay.
    Yes i agree that this does cause interference, but i understand a ground loop is something different. When finding ground, the audio signal is taking the easiest route, which sometimes may be the same route as something else that is drawing power varying power...or something like the alternator constantly changing is power due to revs.... hence it causes interference. so why would a shielded cable straight back to the battery not fix this?? I have only heard good things about ground loop isolators too.

    anyone shed some light?

  5. #5
    Variable Bitrate
    Join Date
    Nov 2007
    Posts
    359
    hence it causes interference. so why would a shielded cable straight back to the battery not fix this??
    DC power cables are not shielded - never seen a sheilded one in my life.

    As for why not to run a earth to the boot:
    1) Price: you will need to use suitable think cable over a long length as to not cause voltage drop.
    2) Difference: with the other electronics grounding to the chassis a direct ground to the battery may have a significantly different level of restiance. Increasing the chances of electrical interference.

    In a moderate powered system I'd always ground to the chassis and make sure i've upgrade my battery to chassis ground, and alt to chassis ground to compensate for the additional current draw.

  6. #6
    Variable Bitrate billmee's Avatar
    Join Date
    May 2005
    Location
    USA
    Posts
    299
    Power ground - noisy components, pc headunit amp, to the same spot.
    Signal ground - the shield of the shielded cables, audio video etc.

    Ground loop - when path to ground is found thru shield to a different components power ground thus picking up a lot of noise

  7. #7
    FLAC
    Join Date
    Oct 2006
    Posts
    1,002
    i never believe in ground loop isolator because its just a high pass filter really, and it does not eliminate the problem, it just hides it. This works better imho http://www.electronixwarehouse.com/c...e-sup/ns10.htm another thing is grounding the computer case worked for my case.
    Also, cross talked between signal and power wire has never happened to me, even if i used cheap RCA cables that are not at all shielded. The problem has always been ground and not clean power.

Similar Threads

  1. PAC SNI-1 Ground Loop Isolator & RCA Noise Filter
    By bambam in forum The Review Palace
    Replies: 6
    Last Post: 02-06-2008, 12:35 PM
  2. Replies: 4
    Last Post: 09-09-2007, 12:28 AM
  3. Re-Ground HU or Ground Loop Isolator?
    By Incinorator in forum Car Audio
    Replies: 5
    Last Post: 04-20-2006, 08:52 PM
  4. Ground loop with an external USB card?? Help! (LONG)
    By vettejock99 in forum Car Audio
    Replies: 18
    Last Post: 02-05-2006, 11:20 AM
  5. Turtle Beach Santa Cruz Sound Card GIVES me a ground loop?
    By rmjjensen in forum General Hardware Discussion
    Replies: 2
    Last Post: 11-15-2003, 08:26 AM

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •