Quote: Originally Posted by NiSlo View Post
Paul,

Is there any support planned for the Subaru SSM protocol? Also, ideally at a baud rate of 56600 how many readings would you expect to be able to get per second?

I think that one would be easy to support, I have some info on the protocol but not complete, if someone was to provide the details I could get that protocol supported, I will look around to see if I can uncover more details.

The # of readings that you can get at the higher baud rate is really dependent on the ECU and what latencies it runs into, on an ISO vehicle you might not get a lot of additional readings. With the increased baud rate you should also look at playing with the ATST (timeout) setting and keep going lower until you see NO DATA messages, this will reduce the time the scantool waits before sending the next command and will help improve the throughput.

Thanks
Paul