Ground Loop - can't I just go direct to terminal?

I'm trying to eliminate my ground loop, alternator whine problem and I'm thinking I'll buy a bunch of wire, and just connect the ground of my P1900 directly back to the battery, i shouldn't hear anything, right? Just the sweet sound of music, correct? I mean, there's no better ground than "ground" itself. (Aside from having RF interfence, but that's a different story)
Red_Beard is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Old 01-06-2008, 04:15 PM   #2
Maximum Bitrate
 
crooper's Avatar
 
Join Date: Nov 2006
Location: Everett, WA
Posts: 465
crooper is an unknown quantity at this point
You need to do some more reading. The "quality" of the ground connection isn't the problem, it's having signal wires in close proximity to power wires and getting crosstalk. Unless you're using like 0 awg wire I don't think there's any real advantage to having wire returning to the battery instead of good bare metal chassis grounds. If you're worried about having good grounds, you could do the Big 3 upgrade in your engine bay.
crooper is offline   Reply With Quote
Old 01-07-2008, 11:24 AM   #3
Low Bitrate
 
Join Date: Apr 2004
Location: Dublin
Posts: 111
djtaz is on a distinguished road
I had a problem with the buzzing sound and i purchased a 'ground loop isolator' for 15 euro that completely solved the issue i was having. Im in Europe so i dont know of places that sell them there , but google it.
djtaz is offline   Reply With Quote
Old 01-07-2008, 03:54 PM   #4
Newbie
 
Join Date: Mar 2004
Location: Australia
Posts: 49
toymachine is on a distinguished road
Quote: Originally Posted by crooper View Post
You need to do some more reading. The "quality" of the ground connection isn't the problem, it's having signal wires in close proximity to power wires and getting crosstalk. Unless you're using like 0 awg wire I don't think there's any real advantage to having wire returning to the battery instead of good bare metal chassis grounds. If you're worried about having good grounds, you could do the Big 3 upgrade in your engine bay.

Yes i agree that this does cause interference, but i understand a ground loop is something different. When finding ground, the audio signal is taking the easiest route, which sometimes may be the same route as something else that is drawing power varying power...or something like the alternator constantly changing is power due to revs.... hence it causes interference. so why would a shielded cable straight back to the battery not fix this?? I have only heard good things about ground loop isolators too.

anyone shed some light?
toymachine is offline   Reply With Quote
Old 01-07-2008, 04:17 PM   #5
Variable Bitrate
 
Join Date: Nov 2007
Posts: 359
pokki is an unknown quantity at this point
Quote:
hence it causes interference. so why would a shielded cable straight back to the battery not fix this??

DC power cables are not shielded - never seen a sheilded one in my life.

As for why not to run a earth to the boot:
1) Price: you will need to use suitable think cable over a long length as to not cause voltage drop.
2) Difference: with the other electronics grounding to the chassis a direct ground to the battery may have a significantly different level of restiance. Increasing the chances of electrical interference.

In a moderate powered system I'd always ground to the chassis and make sure i've upgrade my battery to chassis ground, and alt to chassis ground to compensate for the additional current draw.
pokki is offline   Reply With Quote
Old 01-08-2008, 06:49 AM   #6
Variable Bitrate
 
billmee's Avatar
 
Join Date: May 2005
Location: USA
Posts: 277
billmee is on a distinguished road
Power ground - noisy components, pc headunit amp, to the same spot.
Signal ground - the shield of the shielded cables, audio video etc.

Ground loop - when path to ground is found thru shield to a different components power ground thus picking up a lot of noise
billmee is offline   Reply With Quote
Old 01-13-2008, 02:52 PM   #7
Maximum Bitrate
 
Join Date: Oct 2006
Posts: 707
Punky is on a distinguished road
i never believe in ground loop isolator because its just a high pass filter really, and it does not eliminate the problem, it just hides it. This works better imho http://www.electronixwarehouse.com/c...e-sup/ns10.htm another thing is grounding the computer case worked for my case.
Also, cross talked between signal and power wire has never happened to me, even if i used cheap RCA cables that are not at all shielded. The problem has always been ground and not clean power.
Punky is offline   Reply With Quote
Sponsored links
Advertisement
 
Advertisement
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
PAC SNI-1 Ground Loop Isolator & RCA Noise Filter bambam The Review Palace 6 02-06-2008 12:35 PM
Ground Loop only when I take Faceplate off??? nobb Car Audio 4 09-09-2007 12:28 AM
Re-Ground HU or Ground Loop Isolator? Incinorator Car Audio 5 04-20-2006 08:52 PM
Ground loop with an external USB card?? Help! (LONG) vettejock99 Car Audio 18 02-05-2006 11:20 AM
Turtle Beach Santa Cruz Sound Card GIVES me a ground loop? rmjjensen General Hardware Discussion 2 11-15-2003 08:26 AM



All times are GMT -5. The time now is 10:40 PM.


Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Content Relevant URLs by vBSEO 3.3.2
Copyright © 1999 - 2008 Mp3Car.com Inc.Ad Management by RedTyger
Message Board Statistics